Fixed-Series-Gap Arrester

It is for outdoor distribution system of AC 48 to 62Hz, rating of 10kV.

Fixed-Series-Gap Arrester

It is for outdoor distribution system of AC 48 to 62Hz, rating of 10kV.
Fixed-Series-Gap Arrester

Product introduction:

The working principle of tis arrester is that the lightning overvoltage and operating overvoltage of the protected electrical equipment can be limited by the combination of series gap and zinc oxide nonlinear resistance current-limiting elements. The isolation of series gaps can avoid the single-phase grounding and keep safe operation of the line.

The lightning protection gap is only air, which can be restored. The gap distance is fixed, not affected by the operation environment, so the lightning discharge characteristic is stable. Even if the arrester fails, it can still run for a long time as a lightning protection tool to protect the lines from lightning. The installation and replacement of the arrester can be implemented on the ground through an insulation rod once the bracket installed, significantly reducing the cost of installation, repair and replacement, and making the operation easy and low risky.

Note: Technical datas and sketches are only for your reference. Such details in our contact prevail.


Model annotation:

image.png



Technical parameter:


NOItemUnit
1Nominal voltagekV
2Rated voltagekV
3Continuous operating voltagekV
4Continuous currentkA
5Nominal discharge currentkA
6DC Voltage reference (1mA)        kV
7Residual voltage≤Residual voltage under steep wave impulse current≤kVp
Residual voltage under lightning impulse current≤kVp
Residual voltage under operating impulse current≤kVp
82ms Impulse rectangular currentA
94/10μs high current impulse withstand current      kAp
10Discharge clearancemm
11Insulation voltage of housingLightning inpulse withstand voltagekV
Short-time AC withstand voltagedrykV
wetkV
12Partial discharge ≤     pC
13Creepagemm
14Arrester dimensionInsulator height Lmm
Shed diameter D/dmm
Shed numberpcs
15Varistor diametermm
**Operating residual voltage under 250A


Appearance size: